N285.0-06 General Requirements for Pressure-Retaining Systems and Components in CANDU Nuclear Power Plants

Clause 2
  Question : Are the release dates listed for the codes and standards in Clause 2, Reference Publications, of the CSA Standard N285.0-06, the Effective Dates for the codes and standards to be used for construction?
  Answer : No, the requirements for the Effective Dates which govern the use of the codes and standards in the constructions, repairs, replacement, and modification of pressure retaining items are given in Clause 4 of the CSA Standard N285.0-06.
Clause 7.5.1(a)
  Question : Is it the intent of Clause 7.5.1(a) to allow referencing existing system documents (certified or not) in a design specification to address content requirements as required by NCA-3252, provided that the design specification is certified as required by NCA-3255?
  Answer : Yes.
Clause 10.3 (e)
  Question : Is it the intent of N285.0-06 Clause 10.3 (e) to refer to CSA B51 Annex F for quality requirements for class 6 fittings?
  Answer : Yes.
Clause 11.2 and 11.3
  Question : Do the requirements of 11.2 and 11.3 of CSA N285.0 apply to class 6 pressure-retaining piping or component and exempt from classification but registered piping and component?
  Answer : No. The applicable requirements are contained in CSA B51.
Clause 12.3.1
  Question : Is it the intent of the standard that nameplates and identification required for items specifically identified in 12.3.1 also apply to “parts” and “piping subassemblies” as referenced in ASME III NCA-1230?
  Answer : Yes.
Clause 14.3.2
  Question : Is it the intent of Clause 14.3.2 to apply to replacement instruments registered in accordance with Clause 7.9.1.3?
  Answer : No.
Clause 14.5
  Question : Does a modified component require an additional nameplate when the only change associated with the items listed in Clause 12.3.2 of CSA N285.0-06 is a revision appended to the existing CRN?
  Answer : Yes.
Clause 14.7.2.5 and 14.7.2.6, System Pressure Testing
  Question : Where clauses 14.7.2.5 or 14.7.2.6 permit an operational pressure test to be performed, in lieu of the system pressure test for Class 1, 1C, 2, 2C, 3, 3C, or 4 pressure boundary items, is it permitted to apply the exemptions under Clause 14.7.3.2?
  Answer : No. If an operational pressure test is to be performed, in lieu the system pressure test in accordance with clauses 14.7.2.5 or 14.7.2.6, it is not permitted to use the exemptions under Clause 14.7.3.2. The exemptions from the system pressure test specified in Clauses 14.7.2.1 and 14.7.2.2 are applied to Class 1, 1C, 2, 2C, 3, 3C, or 4 pressure boundary items.
Clause 14.7.2.8
  Question : Is it an intent of the last paragraph of Clause 14.7.2.8 to be applicable to item (b) only?
  Answer : Yes.
Topic: General
  Question : Is the intent of CSA N285.0-06 that a pressure boundary item forming part of Class 1, 2, 3, 4, 1C, 2C, 3C component (eg. Valve's Plug, Compressor's plates) and meeting all the following characteristics, be supplied with a Data Report?
  • Item manufactured by the Original Equipment Manufacturer (OEM) of the component, under an approved QA program;
  • Item manufactured according to the registered design of the component;
  • Item manufactured without welding;
  • Item manufactured with operations that do not change the properties required by the material specification;
  • The item does not require inspection by the ANI or licensee verifier according to the standard.
  Answer : No.
  Question : In CSA N285.0-06 are records required to be retained by the licensee for Clauses 6.1.10.1; 6.1.10.2; 9.3.1; 9.3.2 and 9.3.3 considered as non-permanent records in accordance with Clause 12.2.6?
  Answer : Yes.
Topic: Signing Authority of the Licensee’s Verifier
  Question : Is it the intent of the Committee that the Licensee’s verifier could sign off a data report for a modification for which approval by the authorized inspector is not required?
  Answer : Yes, in accordance with Table 1.
Topic: Statutory Declaration Forms of CSA N285.0-06, Clause 6.1.6, Figure C.1, Clause C.12
  Question : Does a Class 1, 1C, 2, 2C, 3, 3C and 4 fitting registration number have an expiration date?
  Answer : No, provided the manufacturer has a valid quality system program as stated on the Statutory Declaration form and as required by this Standard.
Topic: Supports
  Question : Does an item manufactured from structural element that is used to connect together two or more pipe in a piping system to keep them apart, but is not transmitting any load to the building structure is considered a support as per CSA N285.0?
  Answer : No as per definition of support.
  Question : Does an item manufactured from structural element providing damping thru friction only and that transmits loads to the building structure but does not carry the weight of the pipes need to be considered a support as per CSA N285.0?
  Answer : Yes.